NKL 4200A-GY

NIKOLAN F / UTP cable, 4 pairs, Cat.5e, 24 AWG, Indoor, PVC, 305 M

Order table

P/N Number of pairs Category Type Application Color Length, м Volume, m3 Weight, kg To compare Add to cart
NKL 4200A-GY 4 5e F/UTP Indoor, PVC Gray 305 0.0344 14.6
NKL 4201A-GY 4 5e F/UTP Indoor, PVC Gray 100 0.0070 4.2

Description

NIKOLAN 4 Series cables provide excellent performance at a reasonable price, which makes them the best choice for building networks in projects that do not require system support. The range of internal cables includes shielded (F / UTP) and unshielded (U / UTP) cables of categories 5, 5e and 6 with PVC or LSZH-comand shells. Depending on the specific model, the internal cables of the 4th series are delivered in "easy-pull box" cartons or on plywood drums. Unshielded cables (U / UTP) are the most popular and easy to install type of cable, but they do not have protection against electromagnetic interference. When laying in close proximity to the power lines, it is recommended to refer to shielded solutions.

Characteristics

Category

5e

Bandwidth, MHz

100

Type

F/UTP

Number of pairs

4

Material of conductors

Copper

Type of conductors

Solid

Diameter of conductors, AWG

24 AWG (0.50 ± 0.01 mm)

Insulation material

High density polyethylene (HDPE)

Insulation conductor thickness, mm

0.24 ± 0.02

Diameter of conductor insulation, mm

1.0 ± 0.05

Outer jacket material

Polyvinyl chloride (PVC)

Connection style

Eca

Application

For Indoor Installation

Jacket thickness, mm

0.55 ± 0.05

Outer jacket diameter, mm

6.2 ± 0.3

Jacket color

Gray

Screen construction (common screen)

Polyester aluminum foil, laid in contact with the drainage conductor

Protective film

Yes

Ripcord

Yes

Mass density (kg) per unit length (km)

43.0 ± 0.5

Radius of bending during laying

At least 8 cable diameters

Radius of bending during operation

At least 4 cable diameters

Maximum tensile strength

Not more than 80 N

Characteristic impedance, ohms

100 ± 15

Nominal velocity of propagation (NVP)

0.69 ± 0.1

Max. Conductor resistance(DC), ohms/km

≤ 95

Length, M

305

Compliance

Exceeds the requirements of the standards: ISO / IEC 11801, EN 50173 and ANSI / TIA-568-C.2

Supported applications

10BASE-T, 100BASE-TX, 100BASE-T4, 1000BASE-T, 10GBASE-T (For Cat.6),
ATM-25, ATM-51, ATM-155, 100VG-AnyLan, TR-4, TR-16 Active, TR-16 Passive

Temperature ranges

Storage from -20 to +60 ° C. Installation from 0 to +50 ° C. Operation from -20 to +60 ° C

Individual packing

Cardboard box

Package dimensions (LxW or W x H x D), mm

405x405x210

Warranty

Component warranty - 5 years, system warranty - 15 years

Downloads